Xantrex XM Specifications

Electrical specifications – inverter XM 1000 XM 1800
Output power (continuous) 1000 W 1800 W
Surge rating 2000 W 3600 W
Output current (continuous) 8.3 A 15.0 A
Output voltage range 115 V +/- 10 V 115 V +/- 10 V
Output frequency regulation 60 Hz +/- 1 Hz 60 Hz +/- 1 Hz
Output wave form Modified sine wave Modified sine wave
Peak efficiency 88% 88%
No-load input power (producing output voltage) < 6 W < 6 W
Power draw in standby mode < 2 W < 2 W
Input opearating voltage range 11.0 - 15.5 Vdc 11.0 - 15.5 Vdc
Transfer relay rating 15 A 20 A
Transfer time 40 ms 40 ms
General specifications
Operating temperature range 32°F - 104°F (0°C - 40°C) 32°F - 104°F (0°C - 40°C)
Storage temperature range -4°F - 140°F (-20°C - 60°C) -4°F - 140°F (-20°C - 60°C)
AC receptables 2 2
Recommended DC fuse 150 A 250 A
Unit weight 8.0 lb (3.6 kg) 10.6 lb (4.8 kg)
Unit dimensions (H x W x L) 4.0 x 8.3 x 12.9“ (103 x 211 x 329 mm) 4.0 x 8.3 x 12.9“ (103 x 211 x 329 mm)
Warranty One year One year
Part number 806-1010 806-1810
Regulatory and environmental compliance
ETL listed to CSA Standard C22.2 No. 107.1, UL458 with marine supplement*
Specications are subject to change without notice. *When used with drip shield, part #808-1050.
DS20150514_PROXMCopyright © 2015 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
Smart choice for power
PRO XM1000/1800