Installation Guide

Installation
38 975-0126-02-01
Testing in AC Bypass Mode
To test the MS2000 in transfer mode:
1. Close the AC supply breaker to supply AC power to the unit.
The transfer from invert to AC input power occurs.
2. Press the Charger Enable button to disable the charger. Verify that the Charger
Enable light is not illuminated. AC loads will still be powered.
Testing the Echo Charger
1. Close the Echo Charger disconnect switch or replace the fuse.
2. Check the System screen on the System Control Panel and ensure the
MS2000 is in the Bulk or Absorption charge cycle.
3. From the MS2000 advanced menu on the System Control Panel, verify that
the Echo Charger is enabled.
4. If the Echo Charger is enabled, verify that the MS2000 advanced menu is
displaying the Echo Charger current and voltage.
The current displayed will depend on the voltage level of the house bank and the
voltage difference between the house battery bank and the engine battery.
Inverter/Charger Physical Specifications
For complete inverter/charger specifications, refer to the MS2000 Sine Wave
Inverter/Charger Operation Guide.
The physical specifications of the MS2000 are shown in Figure 18 on page 39 and
described in Table 5.
Table 5
MS2000 Physical Specifications
Length 16.19 inches (411 mm)
Width 14.20 inches (361 mm)
Height 8.1 inches (208 mm)
Weight 67 lbs (30 kg)
DC terminal bolt size 3/8 inch
Ground terminal bolt size 1/4 inch