- Xantrex Solar Inverter Owner's Manual

Monitoring the Inverter
5–10 975-0253-01-01
Status Indicator Lights
The GT Inverter is equipped with two status indicator lights (LEDs) located below
the front panel LCD (Figure 5-2). These LEDs indicate the inverters current
status (Table 5-11) and assist in troubleshooting the performance of the unit.
Only one indicator light will be lit at any time.
Table 5-11
Status Indicator LEDs
LED on Means
Green GT Inverter is on (DC voltage and AC voltage are qualified and the
protection timer has finished) and delivering energy to the grid. No action
required. Turns off when a fault state is detected.
Red Ground fault condition detected.
Check for any fault messages on the display (see Table 5-8), and refer also
to Table 6-1, “Troubleshooting the GT Inverter on page 6–4 to resolve the
fault condition.
Figure 5-2
Location of Status Indicator Lights
Green LED
Red LED