C-Series Meter power Installation Guide C40R/50 Remote, C40R/100 Remote, DVM/C40 Faceplate
10
975-0123-01-01 Rev A
Cable Installation (Step 2)
Connect the display to the controller using the serial communications 
cable provided. The cable is a six-conductor telephone cable with 
modular-type connectors (RJ-15). Although any telephone-type cable 
will work, the cables provided with the displays use stranded and 
tin-plated wire for better performance and longer life. 
The following instructions are illustrated in Figure 6.
To connect the Faceplate to the C-Series controller:
1. Remove the front cover of the C-Series controller by removing the 
four screws on the front cover of the unit.
2. Remove the LED on the circuit board of the C-Series controller 
next to the RJ-15 Port just above the 
BATTERY POSITIVE connector. 
If the LED must be replaced in the future, it will operate in either 
orientation, except if replaced incorrectly, the color of the status 
LED will be reversed. 
3. Insert the serial communications cable from the faceplate into the 
RJ-15 Port.
4. Align the faceplate on the front of the C-Series controller so that the 
holes for the faceplate match. 
5. Secure the faceplate in place using the four screws removed in 
Step 1.