User Manual
Installation
3–12 975-0263-01-01
Connecting the Chassis Ground
The XM Series Inverter has a ground stud on the side of the unit as shown
in Figure 3-3. Follow the guidelines in “Grounding Locations” to connect
the inverter’s chassis to the ground.
Grounding Locations
You must connect the chassis ground stud to a grounding point—usually
the vehicle’s chassis—using recommended copper wire (if insulated then
green insulation with or without one or more yellow stripes) or larger.
For recommended chassis ground cable size, see “Sizing the Chassis
Ground Cable” on page 3–7.
WARNING: Shock hazard
Never operate the XM Series Inverter without properly connecting the chassis
ground. An electrical shock hazard could result from improper grounding.
Figure 3-3
DC Panel Connections
Chassis
ground stud