User's Manual
Table Of Contents
- 1 Introduction
- 2 Safety and warranty
- 3 Product description
- 4 Commissioning
- 5 XorayaSuite
- 6 Maintenance
- 7 Storage, transport and disposal
- 8 Appendix
USER MANUAL
XORAYASUITE
114
Tab
Function and context menu
Interface
Summary of recorded messages and errors grouped by
interfaces and channels
Context menu:
▪ Show or hide columns
▪ Hide inactive interfaces or channels
Message
Summary of recorded messages and errors grouped by
messages
Context menu:
▪ Fix selected rows
▪ Filter data by interfaces or channels
▪ Legend of the error flags
CCP / XCP
Summary of recorded CCP / XCP signals
Context menu:
▪ Fix selected rows
▪ Hide selected messages
▪ Accelerate ECU registration of signals
▪ Represent data graphically (➔ Graph View)
▪ Display physical properties
Signals
Monitoring of defined signals (➔ Signal selection)
Context menu:
▪ Show or hide columns
▪ Hide selected signals
▪ Save, load and delete signal lists
Send
Send user-defined CAN, RS-232 or Ethernet UDP messages once
or cyclically
System signals
Display of system signals (core temperature, for example) as
widgets
Live
Live view of the current recording, where a row corresponds to a
message
Context menu:
▪ Show or hide columns
▪ Filter data by interfaces, channels or CAN/FlexRay IDs
▪ Set Timemaster
▪ Freeze display
▪ Free up display area: Delete displayed rows
▪ Set the number of rows displayed (default: 500)
▪ Set details of the selected row: Specify whether the detail
view will jump to new incoming messages or remains
constant
▪ Represent data graphically (➔ Graph View)
Config
Current ML-N4000 configuration