Technical data
Densitometric functions
............................
4.15
• Position the measuring aperture on the standard colors in the given printing sequence and initiate a
measurement of each color by pressing the <Measurement key>.
• The display indicates the solid tone density values of the standard colors; the printing sequence is
shown in brackets; in the example: B ( 4 ), C ( 1 ), M ( 2 ), Y ( 3 ).
• • • • •
• Position the measuring aperture on a solid tone patch, a halftone patch or an overprint patch and
initiate a measurement by pressing the <Measurement key>.
• The display indicates the printing sequence with the density values of the standard colors and the
corresponding measured values for density, dot gain or trapping.
• Select the menu line Return by turning the <Control ball> and press the <Measurement key> to
return to the main menu.
........................................................................................................................................
The measurements in this example were made with reference to paper white. Measurements
were made of the solid tone patches according to the printing sequence, a 80% halftone
patch, a 40% halftone patch and an overprint patch.
........................................................................................................................................