Certificate Of Compliance

HBCS Report # FCC_12003 Page 6 of 17
2. Test Facility
Radiated Emission testing was performed at Emerson Network Power. This facility is located at
2900 S. Diablo Way, Suite 190, Tempe, AZ 85282. All equipment used in making physical
determination is accurate and bears recent traceability to the National Institute of Standards
and Technology.
Test facility at Emerson Network power is an A2LA accredited test site. The A2LA certificate
number is 2716.01. The scope of accreditation covers the FCC Method - 47 CFR Part 15, ICES-
003, CISPR 22, AS/NZS 3548 and VCCI.
Conducted Emission testing was performed at H.B. Compliance Solutions. This facility is located
at 254 W. Baseline Road, Suite # 103, Tempe AZ-85283.
Radiated Emissions measurements were performed in a semi-anechoic chamber (equivalent to
an Open Area Test Site). In accordance with ยง2.948(a)(3), a complete site description is
contained at Emerson Network Power.
3. Description of Test Sample
The PI Engineering, X-Keys, is a USB keyboard which has been designed to offer extra
programmable keys. It runs off USB power port of a computer which is 5Vdc.
4. Equipment Configuration
Ref. ID Name / Description Model Number Serial Number
# 1 X-Keys XK-16 Stick XK-0981-UCK16 N/A
Table 1. Equipment Configuration
5. Support Equipment
All support equipment supplied is listed in the following Support Equipment List.
Ref ID Name / Description Manufacturer Model # Serial #
2 Laptop Computer Dell D620 RF621A02
Table 2. Support Equipment
6. Ports and Cabling Information
Ref ID Port name
on the EUT
Cable
Description
Qty. Length (m) Shielded?
(Y/N)
Termination Box ID
& Port ID
#3 USB USB 1 2 N Laptop
Table 3. Ports and Cabling Information