Certificate Of Compliance
HBCS Report # EMC_12003 Page 24 of 36
Radiated Immunity Test Data
Test Parameters
Start Frequency (MHz):
80 Stop Frequency (MHz): 1 GHz Test Level (V/m): >3 Spec. Level (V/m):
3
Start Frequency (MHz):
N/A Stop Frequency (MHz): N/A
Test Level (V/m): N/A
Spec. Level (V/m):
N/A
Start Frequency (MHz):
N/A Stop Frequency (MHz): N/A
Test Level (V/m): N/A
Spec. Level (V/m):
N/A
Start Frequency (MHz):
N/A Stop Frequency (MHz): N/A
Test Level (V/m): N/A
Spec. Level (V/m):
N/A
Modulation Frequency:
1 KHz Modulation Type: AM Step Size (%): 1 Dwell Time (Sec.):
10
Modulation Depth (%):
80 Polarities Tested: 2 Sides Tested: 4
Comments: Field Intensity (V/m)
None Height (m) Left Right
EUT Operating Modes: @ 0.4m Min 2.36 2.40
Normal @ 0.4m Max 7.51 8.95
Deviations From Test Standard:
None
EUT Functions Monitored: For EUT’s > 1.5m x 1.5m
LED’s in front panel of the units were monitored for errors and also one of the key was pressed to display character on laptop screen
for errors
Results
Test Criteria -
No degradation of performance was noted.
Frequencies of interest (MHz)
N/A
Scan
Number
Fixed
Frequency
(MHz)
Antenna
Polarity
(V/H)
EUT
Azimuth
Scan
Level
(Vrms/m)
Response/Threshold
(Vrms/m)
Spec. Limit
(Vrms/m)
1
80 - 1000
V 0 > 3.0 None 3.0
2 80 - 1000 V 90 > 3.0 None
3.0
3
80 - 1000
V 180 > 3.0 None
3.0
4 80 - 1000 V 270 > 3.0 None
3.0
5 80 - 1000 H 0 > 3.0 None
3.0
6 80 - 1000 H 90 > 3.0 None
3.0
7
80 - 1000
H 180 > 3.0 None
3.0
8 80 - 1000 H 270 > 3.0 None
3.0