Certificate Of Compliance
HBCS Report # EMC_12003 Page 12 of 36
F
requency Range
( MHz)
55022
, Class A
Limits (dBuV)
55022
, Class B
Limits (dBuV)
Quasi
-
Peak
Quasi Peak
30
–
230
50
40
.5
230
–
1000
57
47
.5
Note 1 – The lower limit shall apply at the transition frequencies.
Table 8. Radiated Emissions Limits below 1GHz – Limits from EN 55022
Frequency
Range ( GHz)
55022
, Class A Limits (dBuV)
55022
, Class B Limi
ts (dBuV)
Average
Peak
Average
Peak
1
–
3
56
76
50
70
3
–
6
60
80
55
74
Note 1 – The lower limit shall apply at the transition frequencies.
Table 9. Radiated Emissions Limits above 1 GHz– Limits from EN 55022
Conditional testing procedure for above 1GHz Radiated Emission Testing:
If the highest frequency of the internal sources of the EUT is less than 108MHz, the measurement shall
only be made up to 1GHz
If highest frequency is between 108MHz - 500 MHz then measurement is made upto 2 GHz
If highest frequency is between 500MHz - 1GHz, then measurement is made upto 5GHz
And if highest frequency is above 1GHz then the measurement shall be made upto 5 times the highest
frequency or 6GHz, whichever is less.