Specifications

System Administration 43
**Seamless={yes, no}
[HideTaskbar={0, 1, 2}]
If set to yes, then the default resolution for ICA
published applications is set to Seamless. Default = no.
This is a command for Wyse Thin OS v4.2 and later only.
The keyword HideTaskbar sets the status of taskbar
when maximizing the seamless window. If set to 1, the
maximized size will be the full screen, the taskbar will be
hidden when maximizing the seamless window. Moving
the mouse over the lowest bottom of the screen (1/4
height of taskbar) will display the taskbar.
This setting in wnos.ini will be saved into nvram if
EnableLocal is set to yes in wnos.ini.
When set Seamless=yes HideTaskbar=2, it removes the
auto-hide taskbar function but it reports the full resolution
to the ICA server in a similar way to HideTaskbar=1.
Serial={COM1, COM2, COM3,
COM4} [Baud={1200, 2400,
4800, 9600, 19200, 38400,
57600, 115200}]
[Parity={None, Even, Odd}]
[Stop={1, 1.5, 2}] [Size={5, 6, 7,
8}] [Flow={None, XON/XOFF,
CTS/RTS, Both}] [Touch={yes,
no}] [Touch_type={elo,
microtouch, fastpoint}]
Configures local serial ports.
Touch set to yes denotes that a serial touch screen is
attached.
Touch type set to elo to denote that an ELO touch screen
is being used. Touch type set to microtouch to denote
that a MicroTouch touch screen is being used. Touch
type set to fastpoint to denote that a FastPoint touch
screen is being used.
NOTE: Parameters must be specified in the order
shown.
**ShutdownCount={0 to 60}
(seconds)
OR
**ShutdownCounter={0 to 60}
(seconds)
Default = 10 seconds. Specifies the number of seconds
to count down before the shutdown sequence starts
upon using the thin client power button when there are
active sessions (Maximum value =60). Set the value to 0
to commence shutdown immediately and prevent the
display of the countdown pop-up dialog box.
TimeServer=server_list
[TimeFormat = {24-hour
format, 12-hour format}]
[DateFromat = {yyyy/mm/dd,
mm/dd/yyyy, dd/mm/yyyy}]
Specifies the SNTP time servers and optionally the
display format. The time and date format setting in
wnos.ini will be saved into nvram if EnableLocal=yes in
wnos.ini.
Table 3 wnos.ini and {username}.ini , Continued