Specifications
System Administration 39
PnliteServer=List of {IP
address,DNS names} with
optional port number for each
entry
ReconnectAtLogon={0, 1, 2}
ReconnectFromButton={0, 1,
2}
List of IP addresses or host names with optional TCP
port number of PNAgent/PNLite servers. Default=Empty.
Each entry with optional port is specified as
Name-or-IP:port, where :port is optional; if not specified,
port 80 is used as the default. If a port other than 80 is
used, the port number must be specified explicitly with
the server location in the form IP:port or name:port. Once
specified, it is saved in the non-volatile memory.
The statement PNAgentServer and Web interface for
Citrix MetaFrame Server is equal to this statement.
NOTE: This and the DomainList command can be used
in {username}.ini, but generally are used only in wnos.ini.
NOTE: The PNAgent/PNLite server list and associated
domain list optionally may be entered in DHCP server
options 181 and 182, respectively. If entered in both
places, the wnos.ini and {username}.ini entries have
precedence. However, {username}.ini will override
wnos.ini if the identical commands (with different
parameters) exist in {username}.ini.
ReconnectAtLogon and ReconnectFromButton:
0 = disable the option
1 = reconnect to disconnected sessions only
2 = reconnect to active and disconnected sessions
Printer={COM1, COM2, LPT1,
LPT2}
[Name=name]
[PrinterID=window_driver]
[Class=classname]
[Enabled={yes, no}]
[EnableLPD={yes, no}]
Configures local printers. The Name specifies the name
of the printer and is required. If the PrinterID is not
specified, the default Generic/Text Only is used.
[Class=classname] is used in ThinPrint print for
TPAutoconnect (the ThinPrint technology of mapping the
printer from the client side). It can group printers to use
the same template on the ThinPrint server side. The
strings PCL5, PS, and TXT are pre-defined classes. The
class can be a string with 7 characters.
If Enabled is not specified, the default is to enable the
printer. If EnableLPD is not specified, the LPD service
will not be enabled. NOTE: The parameters must be
specified in the order shown.
Printer={LPD1, LPD2, LPD3,
LPD4}
[Host= host]
[Queue=queue]
[PrinterID=window_driver]
[Class=classname]
[Enabled={yes, no}]
Defines an LPD printer. If the PrinterID is not specified,
the default Generic/Text Only is used.
[Class=classname] is used in ThinPrint print for
TPAutoconnect (the ThinPrint technology of mapping the
printer from the client side). It can group printers to use
the same template on the ThinPrint server side. The
strings PCL5, PS, and TXT are pre-defined classes. The
class can be a string with 7 characters.
If Enabled is not specified, the default is to enable the
printer. Default = yes. This setting in wnos.ini will be
saved into nvram if EnableLocal is set to yes in wnos.ini.
NOTE: The parameters must be specified in the order
shown. For backward compatibility, LPD is accepted as
LPD1.
Table 3 wnos.ini and {username}.ini , Continued
Command/Parameter Description