Data Sheet
1
st
Line right Matchcode: FTXX
2
nd
Line right Rated Voltage: 310 V~
3
rd
Line right Climate Category: 40/ 105/ 56/ B
2
nd
Line left Capacitance & Tolerance Code: 225K (Basis pF)
Bottom Line Certificates: ENEC, cULUS, CQC & Internal Marking
Top Cover Marking P < 15 Date Code: YWW
Top Cover Marking P ≥ 15 Date Code & Capacitance & Tolerance Code
Product Marking:
Properties Standard File
ENEC10 by VDE IEC 60384-14 40038405
cULus UL 60384-14 / CAN/CSA - E60384-14 E345659
CQC IEC 60384-14 13001104051
Certification:
Properties Test Conditions Lead Diameter [mm] Force [N] condition
Termination Robustness IEC 600668 - 2 - 21 Pull Test 0.5 to ≤ 0.8 10 min. 10 sec.
0.9 to ≤ 1.25 20 min. 10 sec.
Bend Test 0.5 to ≤ 0.8 5 min. 2 cycles
0.9 to ≤ 1.25 10 min. 2 cycles
Mechanical Properties:
Properties Standard
Active
Flammability
IEC 60384-14 max. 24 surge pulses @ 2.5 kV (one pulse every 5 seconds)
Passive
Flammability
IEC 60384-14 in combination with IEC 60381 - 1 & IEC 60695 - 11 - 5
Vibration IEC 60068 - 2 - 6
all 3 directions, 2 hours each @ 10 - 55 - 10 Hz, amplitude 0.75 mm or
10 g
Properties Standard
Damp Heat IEC 60068 - 2 - 78 40°C, 95% RH, 56 days
Temperature
Cycles
IEC 60068 - 2 - 14
5 cycles, upper and lower temperature 30 min. each, 30 sec. transfer
time
Charge/
Discharge Test
IEC 60384 - 14 √2 x UR @ 100 V/μs
Surge Test IEC 60384 - 14 2.5 kV Surge impulses
Environmental Tests:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CREATED CHECKED GENERAL TOLERANCE PROJECTION
METHOD
KaS PSL DIN ISO 2768-1m
DESCRIPTION TECHNICAL REFERENCE
WCAP-FTXX Film Capacitors
MXXP225225K310ACPP26004
ORDER CODE
890334026034CS
SIZE REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE
Pitch 22.5
002.000 Valid 2018-03-01 eiCap 2/8
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.