Problem
Cause
Solution
The crimping is not
acceptable
The crimping height is wrong
Make sure the adjusting
head is correctly set with
reference to the applicator
plate and check the crimping
height obtained
The terminal is not correctly
positioned with reference to
the anvils and punches axis
Verify the correct positioning
of the terminal over the anvil
and, if needed, adjust
Anvils and / or punches are
damaged and / or worn out
Check the punches, anvils
and cutters and, in case of
damages or excessive
wearing, replace accordingly
The wire section is wrong
Make sure the wire section
corresponds to the crimping
height settings
The pull-test outcome is
lower than the expected
value
The press is not set at a shut
height of 135.8 mm while at
bottom dead center
By means of a shut height
gauge, make sure the press
is set at the correct shut
height
The continuous adjusting
head is not correctly set
Make sure the setting of the
continuous adjusting head
corresponds to the values on
the mini applicator plate
The wire section is wrong
Make sure that the setting of
the continuous adjusting
head corresponds to the wire
section being used