Datasheet

Dimensions: [mm]
1000,0 ±2,5
detail A
2,0 ±0,5
1,5 ±0,5
(Scale-1:10)
A
Scale - 1:1
Material
Metallized Fiber
Polyether Urethane Foam
Rayon Paper with acrylic
adhesive
Reactive Polyurethane Hotmelt
Adhesive
Properties Value Unit
Shielding Effectiveness @ 100
MHz
Shielding
Effectiveness
@ 100 MHz
80 dB
Shielding Effectiveness @ 1 GHz
Shielding
Effectiveness
@ 1 GHz
75 dB
Surface Resistance
1)
R
S
0.08 Ω
Electrical Properties:
1)
Measurement equipment: Loresta AX MCP-T370
Operating Temperature -40 up to +85 °C
Storage Conditions (in original
packaging)
< 40 °C ; < 75 % RH
Moisture Sensitivity Level (MSL) 1
Flammability: UL94 V-0 (File Number E474708)
Test conditions of Electrical Properties: +20 °C, 33 % RH if not specified differently
General Information:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION
METHOD
JoV 005.002 2019-01-01 DIN ISO 2768-1m
DESCRIPTION
WE-LT Conductive Shielding
Gasket
ORDER CODE
30302015
SIZE/TYPE BUSINESS UNIT STATUS PAGE
D-Profile eiSos Valid 1/3
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.

Summary of content (3 pages)