User's Manual
Start signal Command | 0x40 Length Status CS
0x02 0x49 0x01 1 Byte 1 Byte
Status:
0x00: Request successfully received and processed
0x01: Operation failed due to invalid parameter
7.5.2 CMD_GET_REQ
This command can be used to query the UserSettings parameters. The respective parame-
ters are accessed by means of the corresponding SettingsIndex.
Parameters with size of two or more Bytes will be transmitted LSB first unless
noted otherwise.
Format:
Start signal Command Length SettingsIndex CS
0x02 0x0A 0x01 1 Byte 1 Byte
Response (
CMD_GET_CNF
):
Start signal Command | 0x40 Length Status Parameter CS
0x02 0x4A 1 Byte 1 Byte (Length - 1) Bytes 1 Byte
Status:
0x00: Request successfully received and processed
0x01: Request not successful
7.5.3 CMD_FACTORY_RESET_REQ
This command restores the default UserSettings of the module. If this was successful, a
software reset of the module is performed in addition.
Format:
Start signal Command Length CS
0x02 0x12 0x00 0x10
Response (
CMD_FACTORY_RESET_CNF
):
Themisto-I reference manual version 1.0 © August 2019
www.we-online.com/wireless-connectivity 35