Figure 3: Power up
4.3 Quickstart example
Sending and receiving: Hello World
Connect the two devices (modules, EV-boards or USB dongles) to a PC. You may need to
install FTDI VCP drivers manually (see ) or using windows update. A minimum distance
of 2 meters between the two devices should be kept at all time to avoid over modulation of
the receiver.
A terminal program, for example hterm, is used to perform the communication via COM
ports. The two corresponding COM ports have to be selected and opened with a default
configuration of 115200 baud, 8 Data Bits, 1 Stop Bit and Parity set to none (8n1).
Make sure the received data is shown also as hex by enabling the corresponding checkbox:
As soon as the module is ready for operation (at start-up or after a reset), the device sends
a
CMD_RESET_IND
message on the UART. Eventually the reset button has to be pushed (or
CMD_RESET_REQ
performed) to trigger a reset and see this message.
Next, the command interface can be used to configure the module or to transmit data. The
MAC_DefaultAddressMode
is 0, which means that all radio frames are broadcasts that can be
received by any other radio compatible device in default settings.
Themisto-I reference manual version 1.0 © August 2019
www.we-online.com/wireless-connectivity 17