User's Manual
701-070801 Rev A This document contains proprietary information,
see proprietary statement on first page.
Page 57 of 85
Figure 65 Preset-Channel-Receive-Bandwidth Page
Table 28 Preset-Channel-Receive-Bandwidth Page Actions
Event Action
“Narrow” button pressed
Select narrow receive bandwidth and invoke Preset-Channel-Save
page.
“Standard” button pressed
Select standard receive bandwidth and invoke Preset-Channel-
Save page.
“Wide” button pressed
Select wide receive bandwidth and invoke Preset-Channel-Save
page.
Cursor-Right button pressed
Move focus to next location in a left-to-right, top-to-bottom
fashion.
Cursor-Left button pressed
Move focus to previous location in a right-to-left, bottom-to-top
fashion.
BACK button pressed Invoke Preset-Channel-Transmit-Deviation page.
NEXT button pressed Invoke Preset-Channel-Save page.
HOME key pressed Return to Preset-Channel-Function page.
The Preset-Channel-Save page shall allow the operator to save the changes made to the channel. The
user shall be prompted. The page is depicted in Figure 66 and the page’s Action/Event table is
contained in Table 29.