User's Manual
701-070801 Rev A This document contains proprietary information,
see proprietary statement on first page.
Page 41 of 85
Table 9 Programming-Mode-Selection Dialog Actions
Event Action
Preset button pressed Invoke Preset-Channel-Function dialog.
Scan button pressed Invoke Scan-Group-Function dialog.
Key button pressed Invoke Encryption-Key-Function dialog.
Transceiver button pressed Invoke Configure-Transceiver pages.
HOME key pressed Return to Home page.
The Programming-Mode-Selection dialog shall be optionally password protected. If the system option
for password protection of programming mode is enabled, the Programming-Password-Entry dialog shall
appear prior to displaying the Programming-Mode-Selection dialog. If the operator enters the correct
password, the Programming-Mode-Selection dialog shall be displayed. If the operator is unable to enter
the correct password, the request to display the Programming-Mode-Selection dialog shall be rejected.
The Programming-Password-Entry dialog is depicted in Figure 46.
Figure 46 Programming-Password-Entry Dialog
The password shall be limited to 12 characters maximum and shall be comprised of the standard ASCII
characters 33 thru 126 (no spaces allowed). After a character is entered it shall be displayed as an
asterisk (‘*’). If the operator enters the correct password, the Programming-Mode-Selection dialog shall
be displayed. If the operator enters an incorrect password, the field shall be cleared and the operator
may try again. The system shall provide a hard-coded password to grant back-door access to Service &
Support personal troubleshooting in the field.
6.4.2.8 Preset Channel Programming
The Preset-Channel-Function dialog shall allow the operator to add, modify, or delete a preset channel.
The page is depicted in Figure 47 and the page’s Action/Event table is contained in Table 10.