User's Manual

701-070801 Rev A This document contains proprietary information,
see proprietary statement on first page.
Page 35 of 85
Information button pressed Invoke Information page
Configure button pressed
When option for password protection of programming
mode is enabled, invoke Programming-Password-Entry
dialog.
Otherwise, invoke Programming-Mode-Selection dialog.
HOME key pressed Return to Home page.
6.4.2.3 Relay Mode
Relay Mode allows the PMR transceiver system to function as a cross-band repeater. All five transceivers
can participate in a relay. If a Relay link is established between two transceivers, a message received on
one transceiver is automatically retransmitted out the other. If a link is established between three or
more transceivers, a message received on one transceiver is automatically retransmitted out all the
others.
When an operator indicates their desire to enter Relay-Mode, they shall first be presented the Relay-
Configuration dialog. This dialog shall allow the operator to select which transceivers will participate in
the relay. Only transceivers installed in the system shall be selectable. The “Terminate” button shall
only be visible if a relay is currently active. The Relay-Configuration dialog is depicted in Figure 37.
Table 6 contains the Event/Action table.
Figure 37 Relay-Configuration Dialog
Table 6 Relay-Configuration Dialog Actions
Event Action
RT1 button pressed Toggle transceiver 1’s inclusion in the relay.
RT2 button pressed Toggle transceiver 2’s inclusion in the relay.
RT3 button pressed Toggle transceiver 3’s inclusion in the relay.
RT4 button pressed Toggle transceiver 4’s inclusion in the relay.
RT5 button pressed Toggle transceiver 5’s inclusion in the relay.
Cancel button pressed Return to Home page.
Terminate button pressed Return to Home page with Relay-Mode inactive.
Continue button pressed Return to Home page with Relay-Mode active.
HOME key pressed Return to Home page.