Pressing the Cancel soft-button or the HOME button shall return the system to the Home page in normal
operating mode. Pressing the Scan soft-button shall return the system to the Home page with the active
transceiver in scan mode. Pressing the Edit soft-button shall invoke the Scan-Group-Edit dialog.
Figure 26 No Scan Groups Warning Dialog
Select Group
1: FIRE
3: HOMELAND
4: N/A
2: POLICE
CancelEdit Scan
Figure 27 Scan Group Selection Dialog
The Scan-Group-Edit dialog, depicted in Figure 28, allows the operator to temporarily remove (or
restore) a channel from the group, providing a nuisance delete feature. This dialog also allows the
operator to temporarily change the priority 2 channel assignment for the group. Any changes made on
this page shall be lost after a power cycle.
All channels in the scan group shall be displayed, both by number and alphanumeric identifier. The
operator shall be able to select whether a channel is included in the scan via a toggle button or
checkbox, or equivalent. This is depicted as a square in the figure, where green means the channel will
be scanned, white means the channel will be excluded. The operator shall also be able to select which
channel, if any, is the priority-2 channel. This should be done via a set of radio buttons, or equivalent.
This is depicted as a circle in the figure. Only one channel can be the priority-2 channel, but the priority-
2 channel is not required.