User's Manual
FLITELINE AVIONICS SYSTEM
PILOT’S GUIDE
Publication No. 150-047012 Page 65
Rev. D Dec 2005
Options for Status Items on General Page:
UNIT TYPE INTERFACE NVG DME HOLD LIGHTING VOLUME
COM/NAV SERIES III YES YES 5VDC YES
COM ARINC 410 NO NO 28VDC NO
NAV FLITELINE 5VAC
ADF
S
T
A
T
U
S
UNIT TYPE
NAV
NVG
NO
DME HOLD
NO
LIGHTING
5VAC
VOLUME
YES
GENERAL
Notes:
The DME HOLD field applies only to the CCN-955 and CVN-252.
Options for Status Items on Interface Page:
INTERFACE COM FREQ UNIT ID
Series III RANGE A (118.000-151.975 MHZ) 1
ARINC410 RANGE B (118.000-136.975 MHZ) 2
BCD RANGE C (118.000-135.975 MHZ) None
RANGE D (117.000-135.975 MHZ)
RANGE E (116.000-151.975 MHZ)
S
T
A
T
U
S
INTERFACE
SERIES III
INTERFACE
S
T
A
T
U
S
INTERFACE
ARINC410
COM FREQ
RANGE A
INTERFACE
(118.000MHz-151.975MHz)
UNIT ID
1
Notes:
The COM FREQ and UNIT ID fields do not apply to the Series III Interface;
those items are automatically set by the radio.
UNIT ID field applies only to the ARINC 410 interface. The id is set by the
installer to match the id of the radio.
The COM FREQ range field applies only to the CCN-955 and CVN-152 with the
ARINC 410 interface. The range is set by the installer to match the capabilities
of the radio.
The FliteLine ADF Control Display may be configured as Series III or BCD.
BCD only applies to the ADF Display.
Options for Status Items on MISC (Miscellaneous) Page:
HOBBS TEMP
- -
S
T
A
T
U
S
MISC
HOBBS
78 HRS
TEMP
30C
Notes:
Hobbs and Temp are for the FliteLine Control Display only.
Software and Firmware Version Numbers are displayed on this page as is the
full manufacturer part number.