Environmental Specification
Operating Temperature:
-10℃-+50℃
Storage Temperature:
-20℃-+60℃
Humidity: Operating and storing 10% to 95%, non-
condensing
Shock: Operational: 25g, IEC 68-2-29
Vibration: Operational: 2g, IEC 68-2-6
Interfaces
USB1.1: Image (thermal & visual), measurement, and
voice transfer to PC
Physical Characteristics
Size: 120mm x 60mm x 30mm (Standard Model)
Weight: 0.265Kg (including battery)
Color: 2 colors alternative
Chief Functions
Image
• Thermal and visual image are available and switchable between each other
• Both thermal and visual images can be controlled either automatically or manually
• All the thermal images have been 2x zoomed in before being displayed on LCD
• All the thermal images are displayed on LCD in Black/ White and multiple
256-level colors.
• Live image can be frozen on camera and captured in flash memory onboard.
• Live thermal image can be 2× zoomed in when there is no menu on the screen.
• Saved image can be transferred to PC via USB extension cable.
Freeze and Save
• Live image can be frozen on camera.
• Frozen image can be captured in flash memory onboard.
• Onboard data of live image can be frozen on camera and captured in flash
memory
• Up to 600 images can be saved and up to 30-second voice annotation can be
saved for each Image
• Voice annotation,visual image and thermal image can be captured in flash
memory
• Frozen or saved image can be processed on board