User manual

User Manual
Technical Specifications
Image Performance
Thermal:
Detector type: Microbolometer UFPA (160 x 120 pixels, 35μm)
Spectral Range: 8-14μm
Field of View/ Focus: 25° x 19°/12.6mm
Thermal Sensitivity:
120mk @30
Electronic Zoom:
Visual:
Built-in Digital Video: CMOS Sensor, 640 x 480 pixels, 2
24
colors
Image Presentation
External Display: 2.2” TFT & 1.2” CSTN high resolution color LCD
Image display 256 level, 8 palettes (Rainbow, iron, B&W, etc)
Video Output: PAL, composite video
Measurement
Temperature Range:
-20-+250
Accuracy: ±2
o
C or ± 2%of reading
Measurement Modes: Auto hot-spot trace, 4 moveable spots, 4
moveable areas (min, max, mean), sound alarm
isotherm
Measurement Correction: Emissivity variable from 0.01 to 0.99 (in 0.01
increment), automatic correction based on optics
transmission, ambient temperature, distance,
relative humidity, and etc.
Image Storage
Type: Built-in Flash memory (8G bit capacity)
File Format:
IRI (An individual file consists of Infrared image,
visual image and voice saved if any)
Voice Annotation: 30 seconds per image
System Status Indication
LCD Display: Camera status test, battery status indication
Sound Alarm Automatic alarm for power shortage
Laser Locator
Classification: Semiconductor A1GaInP Diode Laser
Battery System
Type: Li-ion battery, rechargeable, field replaceable
Operating time: Over 2 hours continuous operation
Charging System: In camera via USB interface from AC adapter or
in external battery charger
Power consumption: 2W