User manual
User Manual
the data on the image will be highlighted by a black background so that the data is
easy to be recognized.
• Laser: To turn on or off the laser locator when viewing live image
• Audio Alarm: To turn on or off the audio alarm for temperature exceeding the
preset value
• Voice Annotat: To enable or disable voice annotation when saving live images
• Temp Unit: To switch between Celsius and Fahrenheit
• Mean: To define the frozen image as mean of different frames.
• Press Button “Menu” or “OK” to confirm the parameter setting and exit “Setup
Analysis” menu.
• Press Button “C’ to cancel the parameter setting and exit “Setup Analysis” menu.
Press “C” again to exit main menu.
Sub Menu Target
• Press Button “Menu” or “>” to enter the option “Setup”. Press Button “ ” to ∨
highlight “Target”
• Press Button “Menu” or “OK” to enter the “Target Setup” option
• The setup parameters menu will then appear. Press “ ”and“ ”∧∨ to move between
each setting, press Button “<”and “>” to alter the values
• Filter: Set it as 1 or 2 according to its corresponding temperature range.
• Emissivity: Set emissivity value between 0.01 and 0.99
• Relative Humidity: Set humidity percentage value between 1 and 99
• Distance: Set distance from target (meters)
• Alarm: Set scene temperature alarm threshold for audible alarm