Physical Characteristics
Housing: Magnalium
Weight: 0.35KG(including battery) 0.274KG(excluding battery)
Size: 154mmx69mmx45mm
System Features
Unique Features
IR Fusion technology allows you overlay the thermal image directly to the corresponding visual image
2.0 Megapixels CMOS delivers extremely crisp visual image, assistance of crisper and better fusion image.
Easily switchable PAL/ NTSC video output simplifies video viewing.
Camera can be controlled by touch screen, buttons, W/T wheel, USB 2.0 interface, and infrared remote controller, enabling the camera use
in any demanded application.
Auto focus for both thermal and visual image which can be realized by simply pressing one button.
Auto gate works as both shutter and intelligent lens cap.
Internal lens is no longer vulnerable and this special design also makes the optional lens’ assembling easy.
Real-time radiometric thermal video recording and JPG image storage facilitate further analysis and report generation.
Ultra large capacity Mini SD memory card and built-in flash memory offer easy in-field storage.
High-speed USB2.0 interface enables real-time data transfer, live video recording and camera control.
Windows-style man-machine interface & status display screen showing component status reinforce the user-friendly feature.
Compact & durable magnalium camera casing raises reliability and operation easiness.
Robust on board analysis enhances operators’ efficiency & productivity.
4 Hours super long working time ensures uninterrupted high efficient work.
Imaging Performance
Output both thermal and visual video to external display..
Transfer live thermal video into PC via USB 2.0 cable.
Zoom in or out thermal image x2.
Auto or motorized focusing of IR lens.
Temperature Measurement
Auto calibration ensures high accuracy.
Auto hot-spot tracing and center-cursor temperature measurement pinpoint the problem.
Up to 4 spots can be analyzed simultaneously in live or frozen or saved images.
Up to 4 areas can be analyzed simultaneously in live or frozen or saved images, showing respective Max, Min or Average temperature within
each area.
Discretional area can be analyzed simultaneously in live or frozen or saved images, showing respective Max, Min or Average temperature
within the area.
2 lines analysis can be done in live or frozen or saved images.
Histogram analysis can be performed on live or zoomed or frozen or saved images.
Isotherm analysis can be done in live or frozen or saved images.