User manual
User Manual
64
C
Exit parameter value adjusting dialog box
C_L
Idle
UP_L
Idle
DOWN_L
Idle
LEFT_L
Idle
RIGHT_L
Idle
DIAL_UP
Idle
DIAL_DOWN
Idle
DIAL_MID
Idle
LEFT_SIDE
Idle
RIGHT_SIDE
Idle
L_SIDE_L
Idle
R_SIDE_L
Idle
C+LEFT_SIDE
Idle
Troubleshooting
The camera does not turn on Battery improperly installed (i..e battery is not locked in place). Remove battery and install correctly.
Battery contacts are dirty. Clean battery contacts.
Battery charge is low. Recharge battery or replace with fully charged item.
Battery performance is poor Battery may be defective. Replace battery.
Image is blurry The target is not in focus. Adjust focus.
Brightness and contrast are inappropriate. Adjust Tmin and Tmax.
Visual image is blurry The target is not in focus. Adjust focus of the visual camera.
Image contrast is low or there is
no image
Temperature set points Tmin and Tmax are inappropriate. Change the lower set point and upper set point
to values that are more consistent with target temperatures.
Emissivity setting is incorrect. This affects the temperature range set points. Check and amend the
emissivity setting.
The lens cap is on. Remove lens cap.
Condensation on camera lens. Place camera in a dry area at room temperature until condensation
evaporates.
Non-uniformity appears in the image. Perform a non-uniformity calibration.
Temperature measurement is
inaccurate
Emissivity setting is incorrect. Check and amend the emissivity setting.
Temperature set points are inappropriate for this temperature measurement. Select Tmin and Tmax
settings that are closer to the target temperature being measured.
The target is not in focus. Adjust focus.
Condensation on camera lens. Place camera in a dry area at room temperature until condensation
evaporates.
Non-uniformity is severe. Press non-uniformity calibration.