User`s guide
17-16
Command Reference Guide
/I Reboot System (Default)
Reinitializes the VMR/NPS unit and offers the option to keep user-defined parameters or
reset to default parameters. As described in Section 5.10.1, the /I command can also
be used to restore the unit to previously saved parameters. When the /I command is
invoked, the unit will offer the following reboot options:
• Reboot Only (Do NOT default parameters)
• Reboot & Default (Keep IP Parameters & SSH Keys)
• Reboot & Default (Default ALL parameters)
• Reboot & Restore Last Known Working Configuration
Availability: Administrator, SuperUser
Format: /I [Enter]
/UF Upgrade Firmware
When new versions of the VMR/NPS firmware become available, this command is used
to update existing firmware as described in Section 16.
Note: When a firmware upgrade is performed, it will take about 15 minutes to
upgrade the VMR/NPS unit.
Availability: Administrator
Format: /UF [Enter]
/TEST Test Network Parameters
Displays a menu which is used to test configuration of the Syslog and SNMP Trap
functions and can also be used to invoke a Ping Command.
Notes:
• In order for the ping command to function with domain names, Domain Name
Server parameters must be defined as described in Section 5.9.5.
• The Test Menu's Ping command is not effected by the status of the Network
Parameters Menu's Ping Access function.
Availability: Administrator
Format: /TEST [Enter]