User`s guide

17-16
Command Reference Guide
/I Reboot System (Default)
Reinitializes the VMR/NPS unit and offers the option to keep user-defined parameters or
reset to default parameters. As described in Section 5.10.1, the /I command can also
be used to restore the unit to previously saved parameters. When the /I command is
invoked, the unit will offer the following reboot options:
Reboot Only (Do NOT default parameters)
Reboot & Default (Keep IP Parameters & SSH Keys)
Reboot & Default (Default ALL parameters)
Reboot & Restore Last Known Working Configuration
Availability: Administrator, SuperUser
Format: /I [Enter]
/UF Upgrade Firmware
When new versions of the VMR/NPS firmware become available, this command is used
to update existing firmware as described in Section 16.
Note: When a firmware upgrade is performed, it will take about 15 minutes to
upgrade the VMR/NPS unit.
Availability: Administrator
Format: /UF [Enter]
/TEST Test Network Parameters
Displays a menu which is used to test configuration of the Syslog and SNMP Trap
functions and can also be used to invoke a Ping Command.
Notes:
In order for the ping command to function with domain names, Domain Name
Server parameters must be defined as described in Section 5.9.5.
The Test Menu's Ping command is not effected by the status of the Network
Parameters Menu's Ping Access function.
Availability: Administrator
Format: /TEST [Enter]