User`s guide

73. Hang-Up String: Although the APS will pulse the
DTR line to hang-up an attached modem, the Hang-Up
string is often useful for controlling modems that do
not use the DTR line. (Up to 48 Characters,
Default = undefined).
Notes:
·
When communicating with the APS via modem,
communication parameters will not be changed
until you exit from command mode and discontinue
the modem connection to the unit.
·
For a list of basic AT commands for the APS-8M's
Internal Modem, please refer to Section 6. For a
complete listing of all available AT commands and
S-Registers, please visit the User's Guide Archive
at the WTI web site:
http://www.wti.com/guides/guidarch.htm
8. Supervisor Mode: Permits or denies access to Supervisor
Mode. When enabled (Permit), and the valid Supervisor
Password is entered, the port will allow access to
Supervisor Level commands. When disabled (Deny), the
port may not enter Supervisor Mode, even when the
Supervisor Password is entered. (Default = Permit).
Note: The Supervisor Mode cannot be disabled at
Ports 1 or 2.
9. Logoff Character: Defines the Logoff Character for this
port. The Logoff Character determines the command(s) or
character(s) that must be issued at this port in order to
disconnect from a second port (Resident Disconnect).
(Default = ^X ([Ctrl] plus [X])).
Note: When redefining the Logoff Character, make
certain to select a character that does not normally
occur in your data. This will prevent the unit from
accidentally disconnecting ports in the middle of a
data transfer. For example, if the Logoff Character is
defined as "s", then the ports will disconnect
whenever the letter "s" is detected.
5-11
Configuration