Configuration
Parameters can be changed using any common serial terminal program. A serial terminal program
that also allows saving and loading of configuration files can be downloaded from
wte.co.nz/tools.html
Start-up operation is always at 9600:8-N-1.
All configuration commands always start with the asterisk ‘*’ character.
All messages that do not start with the * character are processed by the protocol decoder.
All messages are terminated by a Carriage Return character, shown in this manual as <CR>
All commands that accept a value, can have that value read back by using the ‘?’ suffix. E.g.
*TX_FREQ?
Returns
*TX_FREQ=460000000 (for example)
There are some commands that support multiple entries (such as the same command but for differ-
ent ranges). In this case the question mark can be followed by the parameter to be interrogated. E.g.
*RX_RANGE?<CR>
Returns (lists all ranges)
*RX_RANGE=1:8,2000000
*RX_RANGE=2:0,0
*RX_RANGE=3:0,0
*RX_RANGE=4:0,0
To find the first range only, usage would be:
*RX_RANGE?1<CR>
Returns
*RX_RANGE=1:8,2000000
Note: It is a good practice to restart the unit after changing configuration. This can be achieved by
removing power to the unit or sending the *REBOOT<CR> command.