User's Manual
Table Of Contents
- Introduction
- Safety Information
- Operation
- Configuration
- Protocols
- Serial Point to Point Operation
- Input Handling
- Output Handling
- WTE Output Control Protocol
- Store Forward Operation
- Installation
- MReX Firmware Upgrade
- Antenna
- Disclaimer
- Manufacturing marking and labels
- Maintenance
- Product End Of Life
- Product Warranty
- Specification
MReX Transceiver User Manual v1.92 Firmware
!WARNING
LOSS OF CONTROL
• The designer of any control scheme must consider the potential failure modes of control paths and,
for certain critical control functions, provide a means to achieve a safe state during and after a path
failure. Examples of critical control functions are emergency stop and over travel stop.
• Separate or redundant control paths must be provided for critical control functions.
• System control paths may include communication links. Consideration must be given to the implic-
ations of anticipated transmission delays or failures of the link.
Failure to follow these instructions can result in death or serious injury
!WARNING
To comply with both FCC RF Exposure requirements in section 1.1310 of the FCC Rules and
EN50383, antennas used with this device must be installed to provide a separation distance of at
least 8 cm from all persons to satisfy RF exposure compliance.
DO NOT:
• Operate the transmitter when someone is within 8cm of the antenna. EN50383 regulatory
limits have deemed that 8cm is a safe clearance distance from this product while operating
at full power.
• Operate the transmitter unless all RF connectors are secure and any open connectors are
properly terminated.
• Use within 15cm of sensitive electronic devices and medical equipment while operating at
full power.
• Operate the equipment near electrical blasting caps or in an explosive atmosphere. All
equipment must be properly grounded for safe operations.
!WARNING
THIS EQUIPMENT IS NOT INTENDED FOR MAINS VOLTAGES
• The MReX was NOT designed to operate and/or be connected directly to live main voltages. The
MReX must be connected to a certified, suitably rated low voltage DC supply.
Failure to follow these instructions can result in death or serious injury
© WTE Limited, 2020 – Christchurch New Zealand Page 5 of 59