MReX Transceiver User Manual v1.92 Firmware
Both Input 1 and 2 configured to disable all high level processing.
*IN_CONFIG_H=1:0,0,0<CR>
*IN_CONFIG_H=2:0,0,0<CR>
Both input 1 and 2 are configured as per the full example details above.
*IN_CONFIG_L=1:5,20,10<CR>
*IN_CONFIG_L=2:5,20,10<CR>
Configured messages to be transmitted once triggered.
*IN_MSG_L=1:WT1234560A10 IN 1 LOW<CR>
*IN_MSG_L=2:WT1234560A10 IN 2 LOW<CR>
High level messages can be set to anything since they are configured not to be used
*IN_MSG_H=1:<CR>
*IN_MSG_H=2:<CR>
For more details on command usage please refer to the Configuration section if required.