MReX Transceiver User Manual v1.92 Firmware
*SAVE<CR>
IMPORTANT NOTES:
*TX_CAP for efficient transmission the CAP code should be any number that can be divisible
by 8 without remainder.
*RAW_CONFIG inactivity timeout Transmission timer is reset after receiving every character,
to allow transmission to wait this full period after the last character.
*RAW_CONFIG immediate transmission character accepts decimal value from 0-255 to con-
figure a character such as 13 to immediately transmit on a ‘\r’ character system. Setting
*RAW_END=0 waits until the RAW_TIMEOUT period expires before transmission
Disabling SERIAL_LINK
If you wish to disable the RAW protocol:
1. Cycle power to the MReX
2. Issue the command *DEFAULTS<CR>
3. Issue the command *SAVE<CR>
4. Issue the command *REBOOT<CR>
© WTE Limited, 2020 – Christchurch New Zealand Page 30 of 59