MReX Transceiver User Manual v1.92 Firmware
Maximum over the air data rate is 9600 baud. Transmission time for a 100 byte payload at this rate
is approximately 120mS.
NOTE:
While operating using the RAW protocol, the MReX will NOT respond to any configuration
commands 10 seconds after start-up.
After the 10 second start-up delay the MReX will output “RAW ENABLED”. This is to prevent
accidental misconfiguration during normal operation.
Within the first 10 seconds of operation, after processing any valid command, a further 10
seconds is allowed for processing any additional configuration commands.
*SERIAL_LINK
To Enable Serial Point To Point operation, the link can be set up quickly with the command
*SERIAL_LINK<CR>
This command will configure the following defaults (allowing use in 25, 12.5 or 6.25kHz channel
widths):
*TX_PROTO=RAW<CR>
*TX_MODE=WTE_EN<CR>
*TX_CAP=1324560<CR>
*TX_BAUD=4800-4L_6<CR>
*RX_PROTO=RAW<CR>
*RX_MODE=WTE_EN<CR>
*RX_BAUD=4800-4L_6<CR>
*RX_RANGE=1:1324560, 1324560<CR>
*RAW_CONFIG=4,148,0<CR>
Now, set the required frequency to use, in this example 458MHZ:
*TX_FREQ=458000000<CR>
*RX_FREQ=458000000<CR>
Either accept the default values set by the *SERIAL_LINK command or make changes as desired.
Finally, issue the command SAVE to permanently store the configuration
© WTE Limited, 2020 – Christchurch New Zealand Page 29 of 59