MReX Transceiver User Manual v1.92 Firmware
: = the colon character ‘:’
N = number of transmissions (0 = no transmissions, 9 is max transmission count)
, = the comma character ‘,’
D = debounce in 100 ms steps (from 0-255)
, = the comma character ‘,’
R = time in seconds between retransmissions.
Example:
*IN_CONFIG_H=1:1,10,15<CR>
*IN_MSG_L
*IN_MSG_L specifies the low level message that will be transmitted if configured. E.g.
*IN_MSG_L=1:WT1234560A10 IN_1_LOW<CR>
*IN_MSG_H
*IN_MSG_H specifies the high level message that will be transmitted if configured. E.g.
*IN_MSG_H=1:WT1234560A10 IN_1_HIGH<CR>