User manual
47
EN
1.
SET
10 s
2.
10 s
1.
2.
+
Configuring tubular motors
The tubular motors can be individually configured with the help of a cord circuit setting
unit (22).
The following configurations are possible.
◆ Reload the factory settings.
◆ Switching the reversing mechanism after obstacle detection on / off.
◆ Switching shutter compensation on / off
NOTE
Further settings can be undertaken with the help of the optionally available RT ConfigTool.
Please refer to the information on our Website in relation to this (www.rademacher.de).
Loading factory settings during the commissioning process
Automatic end point configuration is available again once the factory settings have
been loaded.
NOTE
We recommend undertaking these settings with two persons.
IMPORTANT
The tubular motor may not be in operation.
Factory settings:
End points: No end points stored
Automatic adjustment of the end points: activated
Reversing after obstacle detection: activated
Reversing after blockage detection: activated
Shutter compensation: activated
First press the set button (11) on the tubular motor and subsequently press the SET button on the cord circuit set-
ting device (22) (possibly a second person carries this out). Press and hold both buttons for approx. 10 seconds.
Additionally switch on the tubular motor (▲/ ▼). Hold all buttons.
After approx. 10 seconds the tubular motor acknowledges loading of the factory settings by briefly running up
and down.