44
EN
4.
2.
3.
1.
SET
SET
SET
STOP
SET
5.
▼
▲
▼
6.
Manual adjustment of end points
Initial installation
For initial installation, the roller shutter engineer can carry out the end point configuration
with the help of the set button (11) on the motor or with a commercially available
cord switch device (22).
Further information can be obtained from the cord switch device operating instructions.
Subsequent modification of the end points with external controllers
If you want to subsequently modify the end points for your tubular motor, you can use
an external switch as set button, as previously shown, or you can use your roller
shutter controller (e.g. Troll Comfort) in order to readjust the endpoints.
Key assignment on cord switch device (22)
Set button
Change direction of
travel (▲/▼)
IMPORTANT
◆ Operating the equipment without a stopper (21) may cause the roller
shutters to run into the roller shutter box and be damaged.
The roller shutters must always be fitted with a stopper (21) or end-rail.
◆ End points must be set in order to switch off the motor when they are reached for
both directions of travel up (▲) / down (▼).
◆ In order to do so, the tubular motor must be fully installed.
◆ Never dismantle the stopper from the final roller shutter lamella.
◆ The roller shutter box must be opened and the set button (11) on the tubular motor
must be freely accessible.
◆ Do not allow the shutters to knock against the mechanical stops and maintain a
safety gap of 2 - 3 cm.
Risk of crushing injuries to the hand when working with the roller
shutter box open.
Never reach into the area of the rotating union when the motor is running.
Manually setting the upper end point and automatically setting the lower end point
First move the roller shutters upwards.
Press and hold the corresponding set button* until the upper end point is reached.
* on the motor, the cord switch device (22) or the external switch.
Release the set button as soon as the roller shutters have reached the desired end point.
The motor stops and the upper end point is stored.
You can correct the end point in small steps by briefly pressing the set button.
IMPORTANT
In the event that a malfunction occurs during configuration, e.g. in the event that the tubular motor only runs for a single rotation even when
the set button is pressed, it is unlikely that the tubular motor is faulty. Possibly the adapter (10) has slipped off of the motor head.
Check and, if necessary, correct the positioning of the adapter (10), see page 49.
Finally, move the roller shutters down. As soon as the roller shutters are fully closed, the tubular motor switches
off automatically. The position of the roller shutters will be stored as the lower end point.
NOTE
In the event that the end point configuration fails, you must reset the tubular motor to the factory setting (see page 47), in order to repeat the process.
Finally, disconnect the tubular motor from the mains for a few seconds. Subsequently, the tubular motor is ready for operation.
IMPORTANT
The set lead (j) must be connected to neutral (f) after configuration of the end points.
or
or
or