User manual
43
EN
End point adjustment
Mortal danger due to tearing off the motor cable (15).
Ensure that the motor cable (15) is not taken up by the rotating union (5) or torn off
during the configuration process.
IMPORTANT
◆ Operating the equipment without a stopper (21) may cause the roller
shutters to run into the roller shutter box and be damaged.
The roller shutters must always be fitted with a stopper (21) or end-rail.
◆ End points must be set in order to switch off the motor when they are reached for
both directions of travel up (▲) /down (▼).
◆ The tubular motor must be fully installed.
◆ There must be a suitably fixed limit (e.g. window sill) in the area of the lower end
point if the end point is to be configured automatically.
◆ The set lead (j) must be connected to neutral (f) after
configuration of the end points.
Automatic configuration of the end points
This factory setting can be used in order to automatically search for and configure the
end points for the tubular motor.
NOTE
In the event that the end point configuration fails, you must reset the tubular motor to
the factory setting (see page 47), in order to repeat the process.
Requirements for automatic configuration of the end points:
◆ The catch (8) must be mounted with the freewheel mechanism activated (see
Figure 4.a, page 36).
IMPORTANT
◆ The tubular motor may not be disconnected from the mains during the automatic
end point configuration process. The mains connection must be ensured continuously.
First move the roller shutters upwards.
In order to do so, depending on the tubular motor installation situation, press the up (▲) button or down (▼) button for the tubular motor.
IMPORTANT
a) First move the roller shutter upwards when automatically adjusting the end points.
If the roller shutters first move downwards, then the direction of travel must first be reversed.
The roller shutters will travel to the upper limit point and switch off briefly.
Afterwards, the tubular motor will reverse and the roller shutters will move downwards.
As soon as the roller shutters are fully closed, the tubular motor switches off automatically. The position of the
roller shutters will be stored as the lower end point.
Subsequently, the roller shutters will travel up again and then switch off. This position will be stored as the
upper end point.
IMPORTANT
b) The roller shutter should remain at the upper end point following automatic adjustment.
c) The end points cannot be correctly adjusted if the two conditions a) (see Point 1) and b) are not met. In this
case, reset the tubular motor to its factory settings (refer to page 47) and repeat the process.
NOTE
The roller shutters will be protected during standard operations, due to the fact that they will not be tensioned by knocking against the stopper.
Finally, disconnect the tubular motor from the mains for a few seconds. Subsequently, the tubular motor is ready for operation.
IMPORTANT
The set lead (j) must be connected to neutral (f) after configuration of the end points.
You have various options for configuring the end points, which are
described in the following section:
◆ Automatic configuration of the end points.
◆ Manual configuration of the end points:
- Manually setting the upper end point and setting the lower end point by means
of obstacle detection.
- Setting the upper end point by means of blockage detection and manually setting
the lower end point.
- Manually setting the upper end point and lower end point.
Important relationship between the configuration of the lower end
point and installation of the catch.
◆ If the catch is mounted without the freewheel mechanism, then the tubular motor
will not switch off automatically, as it will not detect an obstacle and the lower end
point will not be detected.
◆ If the catch is mounted with the freewheel mechanism, then the tubular motor
will switch off automatically as soon as the freewheel travel is overcome and the
roller shutter lamella are closed.
4.
2.
1.
▲
▼
5.
3.
6.