User manual

41
EN
11
(a)
(b)
(c)
(d)
(e) (f) (g)
(h)
(i)
(j)
12
(a)
(b)
(c)
Electrical connection of the tubular motor (Figure
k
)
Control of a drive from a single point with a 1-pole switch / button
Legend
(a) = set button (11)
(b) = Controller (e.g. 1-pole switch / button)
(c) = Mains 230 V/50 Hz
(d) = Socket box
Pin assignment
(e) = PE green / yellow
(f) = N blue
(g) = L1 black
(h) = () black
(i) = () brown
(j) =
white (set lead)
IMPORTANT
The set lead (j) must be connected to neutral (f) after configuration of the end points.
Parallel connection of several motors (Figure
l
)
Installation example
It is possible to connect numerous RADEMACHER tubular motors in parallel. The number of motors to be
connected in parallel is dependent on the capacity of the switchgear and circuit-breakers.
NOTE
It is not possible to control individual motors if the equipment is connected in parallel.
End point adjustment
If several motors are connected in parallel, it is still necessary to set both end points for each tubular motor,
either automatically or manually, see page 43. In order to do so, the set button for each tubular motor must
be accessible.
IMPORTANT
For this reason, the set lead (j) for each individual tubular motor must be laid up to the respective junction
box, enabling subsequent manual configuration of the end points at any time.
Parallel connection with blinds switches or blinds buttons
RADEMACHER blinds switches or blinds buttons enable up to 5 motors to be switched in parallel.
Parallel connection with RADEMACHER controllers (e.g. Troll Comfort)
Please refer to the technical data for the respective number of motors that can be connected in parallel.
Legend
(a) = Junction box
(b) = Switchgear e.g. 1-pole switch / button
(c) = Mains 230 V/50 Hz