User manual
40
EN
STOP
(11)
L1
L1
N
PE
(15)
10
1.
Safety information regarding the electrical connection
Danger due to electric shock when working on all electrical systems.
◆ The electrical connection for the tubular motor and all work on the electrical systems
may only be undertaken by an authorised qualified electrician and in accordance with
the connection diagrams in these instructions.
◆ Disconnect all poles from the mains and secure them against unintentional recon-
nection.
◆ Check that the system is dead.
◆ Always undertake mounting and connection work with the equipment disconnected
from the mains power.
Risk of short-circuit resulting from damaged cable.
◆ Lay all cables in the roller shutter box so that they cannot be damaged by moving
machinery.
◆ The mains connection for the drive may only be connected with the same conduction
type. Consult customer services if necessary.
Fixed-installation devices...
...must be equipped on the installation side with a circuit-breaker for each phase in
accordance with DIN VDE 0700. Switches with a contact opening width of min. 3 mm
can be used as circuit-breakers (e.g. power switch, power circuit breaker or residual-
current-operated circuit-breaker).
Risk of short-circuit resulting from water in the event of improper cabling.
Never lay the motor cable (15) vertically upwards, as otherwise water may collect on the
cable and run into the motor, leading to damage. Lay the cable in a loop. The loop will
cause any water on the cable to collect at the lowest point, from where it can drain off.
The motor cable (Figure
j
)
Feed the motor cable (15) into the designated junction box or termi-
nal box after hooking the motor in place.
Colour scale for the motor leads (15)
= set lead (white)
L1 =
(black) *
L1 =
(brown) *
N = neutral (blue)
PE = earth (green / yellow)
(11) = Set button on tubular motor
* NOTE The actual direction of rotation for the tubular motor and the roller shutter
depends on the direction of installation and the wiring of the tubular
motor.