Instructions
EN
84
Awning automatic
Outdoor temperature block
Menu Settings
Use outdoor temperature block
No • Yes
If „Yes“:
Type of temperature input object
1 Bit • 16 Bit
If „1 Bit“:
Permits shading if bit = 0
Blocks shading if bit = 1
If „16 Bit“:
Treshold value in 0.1 ° C
-300 … (50) … 800
Hysteresis in 0.1 ° C
1 … (20) … 100
Blocks shading if MV < TV
Permits shading if MV > TV + HY
Send current blocking status
No • Yes
Dawn and time control
Menu Settings
Use dawn and time control
No • only dawn control • only time control • both
(OR gating))
If „only dawn
control“:
Type of dawn input object
1 Bit • 16 Bit
If „1 Bit“:
Switching delay 1 minute
If„16 Bit“:
Dawn treshold value in lux
1 … (10) … 1000
Switching delay 1 minute
Send current dawn status
No • Yes
If „only time
control“:
Time control only by means of communication object
If „both (OR
gating)“:
Excecute settings as shown above
Under „Automatic mode“ the setting „Internal automatic mode“ was selected for „Awning control“.