Instructions
EN
82
Awning control
Blocking object 1 / 2
Menu Settings
Use blocking object 1
No • Yes
If „Yes“:
If blocking object value = 1
no action • stop • retraction command •
extension command
If blocking object 1 value = 0
◆ In case of manual operations before and after blocking
no action • move to last position
◆ In case of automatic operation after blocking
Follow automatic
Value of the object before 1
st
communication and restoration of bus voltage
0 • 1
Use blocking object 2
No • Yes
If „Yes“:
Use settings “blocking object 1” see„Blocking object 1“
Wind block
Menu Settings
Use wind block
No • Yes
NOTE
When blocking, the awning retracts
If „Yes“:
Type of input object
1 Bit • 16 Bit
If „1 Bit“:
Waiting time in safe position in min. after wind block
0 … 255
Behaviour after waiting period:
◆ In case of manual operation before and after wind alarm no action • move to last position
◆ In case of automatic operation after blocking
Follow automatic
If „16 Bit“:
From wind speed in m/sec up-command
2 … (5) … 30
Waiting time in safe position in min. after wind alarm
0 … 255
Behaviour after waiting period:
◆ In case of manual operation before and after wind alarm no action • move to last position
◆ In case of automatic operation after blocking
Follow automatic
Send current blocking status
No • Yes
Alarm object
Menu Settings
Use alarm object
No • Yes
If „Yes“:
If alarm object value = 1
no action • stop • up-command • down-command
If alarm object value = 0
◆ In case of manual operations before and after alarm
no action • move to last position
◆ In case of automatic operation after alarm
Follow automatic
Value of the object before 1
st
communication and restoration of bus voltage
0 • 1