What to do if... ?
...the motor fails to start?
Possible cause:
Mains power not available.
Solution:
Check the power with a meter to ensure that the supply voltage (230 V/50 Hz)
is available and check the wiring.
Observe especially the information relating to impermissible connection types.
...The tubular motor stops after a short period of time during the
configuration and test procedures?
Possible cause:
The adapter (10) may have slipped off of the magnetic ring (19) on the drive
head (12).
Solution:
Check that the adapter (10) sits flush with the drive head (12) and is fully inserted
into the rotating union (5).
Slide the adapter (10) back so that it is flush with the drive head (12) and slide
the rotating union (5) fully onto the adapter (10), see Figure
. Re-adjust the end
points if necessary, see page 60.
...Automatic adjustment of the lower end point does not work.
Possible cause:
The catch (8) is mounted without the freewheel mechanism.
Solution:
Configure the lower end point manually (see pages 64 and 65).
...The tubular motor stops between the two end points during normal
operation?
Possible cause 1:
The bearing capsule (4) may not be secured with a screw to the rotating union (5)
(see Figure ), causing the rotating union (5) to slip from the motor and the
adapter (10) to come away from the magnetic ring (19) on the drive head (12).
Solution 1:
Check for correct fitting of the bearing capsule (4) and the adapter (10). Use a
self-locking bolt to secure the bearing capsule (4) to the rotating union (5) and
remount the motor in accordance with the information on pages 52 - 56.
Possible cause 2:
The thermal protection system has triggered.
Solution 2:
Wait approx. 20 minutes until the motor has cooled down.
...The roller shutters stop during upward or downward travel?
Possible cause:
Iced-up roller shutters or obstacle on the guide rail.
Solution:
Move the roller shutters a short distance in the respective opposite direction.
Rectify iced-up roller shutters or obstacle.
i
XLIM xx
Technical specifications RolloTube X-line
Motor series
i
20
16
230
50
145
0.64
4
5
0.75
2.5
32
H
I
IP 44
487
45
70
30
16
230
50
191
0.83
4
5
0.75
2.5
32
H
I
IP 44
546
45
70
40
16
230
50
198
0.86
4
5
0.75
2.5
32
H
I
IP 44
546
45
70
50
12
230
50
205
0.89
4
5
0.75
2.5
32
H
I
IP 44
546
45
70
10
16
230
50
112
0.49
4
5
0.75
2.5
32
H
I
IP 44
487
45
70
Nm
RPM
V
Hz
W
A
Min.
mm
2
m
R
mm
mm
dB(A)
Rated torque:
No-load speed:
Rated voltage:
Frequency:
Rated output:
Power consumption:
Cyclic duration factor (KB):
Number of wires:
Core cross section:
Plug-in connecting cable (PVC):
Limit switch range: (number of revolutions)
Insulation class:
Protection class:
Protection class in accordance with VDE 700:
Motor length without bearing:
Tube diameter:
Noise pressure level (LpA):