Instructions
51
EN
10. Manual adjustment of end points
1. Move the roller shutters in the desired direction.
i
In the event that a malfunction occurs during the configuration, e.g. the tubular motor only runs for a single rotation
even when you press and hold the set button, the adapter (10) may have slipped off the drive head (12).
◆ Check and, if necessary, correct the positioning of the adapter (10), see page 53.
Switch off the mains power supply after successfully setting the end points and reconfigure the original connection
in accordance with the connection diagram [ 27 ] on page 48 if you have carried out the setting with a cord-switch
setting unit.
= direction of
travel 1
= direction of
travel 2
With the SET button or ON switch
(direction of travel 1 or 2)
2. In addition ...
press the set button on
the tubular motor.
Press/tap the ON switch or SET
button for the opposite direction
twice and engage/press and hold
the third time.
3. Release the button again as soon as the
desired end point is reached.
4. You can correct the end point in small steps by
briefly pressing the button.
5. Switch off the specified direction of travel after
successfully setting the end points.
The respective end point is stored.
Set the Venetian blind
switch to the neutral
position and release
the set button.
Set the switch to the middle
position and ..
release the set button.
With the set button on the
tubular motor
With the cord-switch
setting unit
OR
SET
ON
ON
ON
SET
or
ON
SET
or
SET