User manual

54
EN
i
6. Technical Specications
Power supply
Supply voltage: 230 V ~ / 50 Hz
Nominal power: 70 W
Consumption: Standby: < 0.5 W
Mechanical capacity:
Nominal torque: 10 Nm
Maximum speed: 30 rpm
Maximum tractive force:
See page 81 / Tractive force
diagram
Operating conditions
Transient operation (KB):
4 minutes
(maximum running time)
Protection class: II
Protection type:
IP20 (only for use in dry
rooms)
Number of switching times: 2 (up and down)
Mains connecting cable:
2 x 0.75 mm
2
(H03VVH2-F)
Permissible ambient tem-
perature:
0 °C to +40°C
Noise pressure level (LpA): ≤ 70 dB(A)
Conduct in the event of power failure
The indicator light ashes in the event of a power
failure.
The ashing is switched o by pressing the UP ( ▲ ) or
DOWN ( t ) button.
Data retention subsequently to power failure
The configured switching times are retained after a
power failure. As soon as the power supply is restored,
the opening and closing times will be executed again.
However, the times will be oset by the duration of the
power failure.
Example:
Power failure from 19:30 - 19:45 hours.
The closing time was previously set to 19:30 hours.
The roller shutters will close at 19:45 hours due to
the duration of the power failure.