User manual

36
EN
18.2 Switching times (opening and closing times) [ / ]; brief description
SENSOR (only for closing times [ ] )
The closing time is controlled by a light sensor in
relation to the level of brightness.
In addition, the measured twilight value is linked to
the previously congured closing time. The congured
closing time is interpreted as "latest at xx:xx hours".
1.
Call up the main menu.
18.2.1 Menu 2 - Conguration of opening and closing times [ / ].
2.
Menu "2" [ ] select and
open switching times.
3.
Activate and conrm the
switching times.
On = Switching times on
OFF = Switching times o
4.
Select and conrm a
switching time block.
If the function is not acti-
vated, proceed at point 5.
1 = The switching time set-
ting is realised with a
switching time mode.
2 = The switching time
setting is realised
without a switching
time mode.
Example a:
In winter dusk begins, for example, at approx.
17:00 hours.
The closing time has been set to 20:00 hours.
Your roller shutters will close at 17:00 hours.
Example b:
In summer dusk begins, for example, at approx.
22:00 hours.
The closing time has been set to 20:00 hours.
Your roller shutters will close at 20:00 hours.