User manual

19
EN
13. End point adjustment
IMPORTANT
The end points must be congured in order that the roller shutters stop at the desired upper and lower positions. It is imperative that
both end points are congured, otherwise malfunctions may occur.
If the RolloTron Standard is operated without an end point setting, the drive will continue to run for as long as one of the two
control keys is actuated.
The automatic functions remain blocked until such time as the end point setting is congured.
Set the upper end point
1.
+
Simultaneously press and hold the
buttons.
The roller shutters travel up.
NOTE
Tighten the belt slightly, until it is ten-
sioned by the weight of the roller shutters.
2.
+
Release the buttons...
...as soon as the roller shutter achieves the
desired position for the upper end point.
The roller shutter stops and the upper end
point is stored.
IMPORTANT
Do not set the upper end point right up to the limit stop.
Release the key promptly and never allow it to extend
beyond the respective end point. Failure to do so can
cause overloading and may damage the roller shutters
and / or drive.
i