User manual
78
EN
20. What to do if... ?
Fault Possible cause / solution
... the RolloTron Swivel Winder Standard indicates
no functions?
Check the power supply incl. connecting cable and plug.
... the RolloTron Swivel Winder Standard fails to react
at the congured switching time?
a) There may have been a power failure. Recongure the switching
times, see page 72.
b) The end points may not be congured. Recongure the end points,
see page 68.
... the indicator light (LED) is ashing?
There may have been a power failure. Recongure the switching times,
see page 72.
... the roller shutters no longer stop at the congured
end points?
The end points may be displaced due to elongation of the belt. Re-
adjust the end points, see page 68.
... the roller shutters stop as soon as the operating
button is released?
The end points are not congured. Congure the end points, see
page 68.
... the RolloTron Swivel Winder Standard rotates in the
wrong direction?
Possibly the belt is wrapped around the reel incorrectly, see
page 65.
... the roller shutters stop suddenly during upward
travel?
a) The drive may be jammed, for example, due to the roller shutters
freezing up or other obstacles.
b) The roller shutters may not be running suciently smoothly.
Check the roller shutters and roller shutter guides.
d) The roller shutters may be too heavy. The maximum tractive force
of the belt winder has been exceeded, see page 81.
i