7. Safety instructions
Exceeding the maximum permissible running time
(KB) may overload and damage the RolloTron Swivel
Winder Standard.
◆ The maximum permissible running time for a cycle
may not be exceeded when the equipment is in
operation. For this reason, the RolloTron Standard
swivel winder has an automatic running time limit
(KB) of four minutes.
◆ If the running time limit is triggered, then the
RolloTron Swivel Winder Standard must be left for at
least 12 minutes to cool down. During this period,
the indicator light ashes rapidly. Full operational
availability is re-established after approx. one hour.
i
According to DIN EN 13659, it is necessary to determine
that the movement conditions for the shutters are main-
tained in accordance with EN 12045.
◆ The displacement must be of at least 40 mm on the
lower edge in the rolled-out position with a force of
150 N in the upwards direction.
◆ In doing so, it must be ensured that the extending
speed of the shutters for the nal 0.4 m is less than
0.15 m/s.