Installation & Assembly
Operating conditions
Recommended flow temperature
≤ °65 C
Maximum flow temperature
momentary ≤ °90 C
Minimum flow pressure 1 bar
Maximum flow pressure 5 bar
Recommended operating pressure
3 bar
Test pressure
16 bar
Before installing the val ve s,
clea n the wa ter pipe thoroughly
to avoid dirt and deposits
No tes
232150 1 232150 1C 2321501B
unit:inch mm ( )
Ø1.4"(Ø35)
3 8/ "
1.
3.Screw flexible hoses (11) under
the bo dy (1)
4.Insert washer (6) and SS304
washer (7) through threaded rod (2)
5.Screw hexagonal lock nut (8) on to
thre aded rod (2) and tighten.
6.Screw the nut (8) with screws (9)
to fix the f aucet body (1)
Screw flexible hoses (10) under
the body (1)
2.Screw threaded rod (2) under body (1),
3. Atta ch the O-ring (3) to the base of
faucet b ody
4.Insert t he plate(4)and washer(5)
under the body
4.9"(125)
2"(50)
COLD
HOT
1
10
9
8
6
7
5
3
4
11
2